Uncertainty & measurement

Instrument readings & zero error

Correct zero offsets and combine reading uncertainties.

Your measurements

Number formats & units

Use decimal dots in datasets. Single values also accept decimal commas and scientific notation such as 1.2e-3 or 1.2 × 10⁻³.

Instrument Resolution & Zero Error Calculator inputs

Calculated locally. No account or uploads.

Result & working

Example

The calculator is loading. You can read the worked example below.

Copy & export

Formula & example

The relationship

corrected value=observed value−signed zero offset\text{corrected value}=\text{observed value}-\text{signed zero offset}
Δx=NreadingsΔreading+Δzero\Delta x=N_{\mathrm{readings}}\Delta\text{reading}+\Delta\text{zero}
What the variables mean
SymbolMeaning
Zero offsetWhat the instrument reads when it should read zero. For a two-reading difference, enter the net offset (often zero).
ΔreadingHalf/full resolution or the supplied absolute uncertainty.
Δzero\Delta \text{zero}Uncertainty in the applied correction, zero if treated as exact.

Worked example

Observed reading
12.4
Signed zero offset
0.2
Smallest scale division / display increment
0.1
Reading uncertainty convention
Half a division per reading
Number of readings in the measurement
One reading
Absolute uncertainty in zero correction
0.05
Reading unit
mm

(12.2 ± 0.1) mm

Follow the example steps
  1. Corrected value = 12.4 − (0.2) = 12.2 mm.
  2. Reading uncertainty under the selected half convention = 0.05 mm.
  3. Absolute uncertainties add: 1 × 0.05 + 0.05 = 0.1 mm.
  4. Rounded result: (12.2 ± 0.1) mm.

Common mistakes

Subtract the signed zero offset.

Incorrect approach

5.0 − 0.2 = 4.8

Correct approach

5.0 − (−0.2) = 5.2

More checks before you submit
  • Do not confuse resolution, precision and accuracy.
  • Subtract the signed zero error, not its magnitude.
  • An offset correction does not eliminate uncertainty in the correction itself.
Method notes

A positive zero offset is subtracted; a negative offset is also subtracted and therefore increases the corrected reading. For a length obtained by subtracting two scale readings, enter the observed difference and choose two readings.

Half a division is a common starting convention for an analogue scale. A digital display may be assigned one last digit, half a step, or a manufacturer specification. Follow the actual task; neither choice is a universal IB requirement.

Two readings can share a calibration offset that cancels in their difference. The displayed addition rule is a conservative convention for the uncertainty components you supply; do not count a cancelled offset again.